Henan Zhongsui Engineering Equipment Co., Ltd.
Shield boring machine back up battery tunnel locomotive charging technology
- Nov 15, 2017 -

1.    The battery is added to the relative density, and the battery fluid is 1.25 plus or minus 0.05

440A/h each battery is about 8.5kg x 55 x 2=950kg

560A/h each battery is about 11kg x 96 x 2=2112kg

2.    The battery box is cooled with tap water, and the battery box has water outlet holes and overflow holes

3. After put battery liquid static 4 to 8 h, control the temperature below 35 ℃ then recharging

4. When start charging, you must have a positive negative matching.

5. Spriral rheostatic usage. (adjust current)